MCC - Fatal error when creating a multimedia queue from a client computer

$
0
0
Article ID: 52251 - Last Review: March 19, 2015

PROBLEM

When using YourSite Explorer from a client computer you attempt to create a multimedia queue, and encounter a fatal error. 



SYMPTOMS

Error: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> System.IO.FileNotFoundException: Could not load file or assembly 'Microsoft.IdentityModel, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. 



CAUSE

A needed .DLL file was not copied to the client computer. 



RESOLUTION

Note: This issue is pegged to be resolved in MiCC Version 7.1.2.1.

For previous versions, you can correct the issue by doing the following:

1. On the MiCC server go to [InstallDir]\CCM\Applications\YSE\ .
2. Copy the file Microsoft.IdentityModel.dll to a network accessible location or other way of transporting the file.
3. On the client computer, copy the above file to [InstallDir]\CCM\Applications\YSE\ .
4. Re-launch YourSite Explorer.  Queue creation will now function as expected.



APPLIES TO

MiCC Version 7.1.1.0, 7.1.1.1, 7.1.2.0 

Keywords: fata error yse yoursite explorer Microsoft.identitymodel Microsoft.identitymodel.dll dll