Best Practices when the Site Has Experienced a Power Outage or Other Unplanned or Planned PBX Outage.

$
0
0
Article ID: 52263- Last Review: April 22, 2015

PROBLEM

The site has experienced a power outage, or another planned or unplanned PBX outage.

This frequently results in issues with communication between the CCM server and the PBX. This is because when a site loses power and then regains it, the CCM server usually finishes booting before the PBX does, and as a result, several CCM services connect improperly to the PBX.



SYMPTOMS

Data collection is generally unaffected.

Users may be reporting problems with Interactive Contact Center (where they can change their Make Busy status, or put queues into DND, from Contact Center Client.

If the site uses IVR, IVR may not function correctly.


RESOLUTION

Please follow the same procedure you would follow after a planned PBX reboot (for example, when upgrading the MCD version).  The procedure is described here:  http://micc.mitel.com/kb/KnowledgebaseArticle52262.aspx?Keywords=52262#post-update

NOTE: This procedure will interrupt Data Collection. If the site does not use IVR, and data accuracy is more important to the customer than the availability of Interactive Contact Center functionality, we recommend that you perform this procedure after hours, or during a maintenance window. The procedure will take approximately three minutes.



LIMITATIONS (symptoms which indicate a different problem)

The following symptoms are indicative of more serious issues:
 
    - Media Server Offline Alarms 
    - Contact Center Client real-time monitors are greyed out, and at the bottom of the screen, you see "Connecting on port 5024". This problem may be intermittent.

If you see any of these problems, please refer to this article instead:  http://micc.mitel.com/kb/KnowledgebaseArticle52264.aspx



APPLIES TO

CCM - All versions, when used with a Mitel 3300

Keywords: 

Collector  Mitai Proxy  Restart  Shutdown  Power Outage  Power Failure  ICC  Interactive Contact Center   Interactive Contact Centre  Agent Group Presence  Make Busy  Makebusy  DND  Contact Center Client  CCC  Best Practice  Best Practise 