Quantcast
Channel: Mitel MiContact Center Knowledge Base
Viewing all articles
Browse latest Browse all 959

ALM0073 - Report Meter Pulses

$
0
0
Article ID: 51520 - Last Review: June 22, 2018

DESCRIPTION

Report Meter Pulses is set to "Yes" on the PBX .

Select "Yes" if meter pulses are to be included in SMDR reports. The number of reversals (meter pulses) received from an outgoing trunk can be recorded when this option is selected. The range is 0 to 64000. Leading zeros are output. The maximum number of digits recorded reduces from 26 to 20. The trunk group must be programmed for “Answer Supervision”. This field is not used for internal SMDR. 

SEVERITY

Minor 



IMPACT

This option must be set to "No" for accurate reporting. If set incorrectly, five zeros will append to the digits dialed column of SMDR records.



TROUBLESHOOTING STEPS

1. Open the 3300 ESM.
2. On the left, click on System Properties =>System Feature Settings =>SMDR Options.
3. Click Change.
4. Set Report Meter Pulses to No.
5. Click Save.

NOTE: This alarm will need to be cleared manually by going to YourSite Explorer and clicking on Alarms.  Select the alarm in question and click the Snooze button.


APPLIES TO

6.0 SP1 

Keywords: Meter Pulses digits dialed SMDR ALM0073