Article ID: 52253 - Last Review: March 26, 2015
2. Go to the Application Pools page.
3. Select the CCMWa application pool.
4. Under Actions, click on Stop.
5. Under Actions, click on Start.
PROBLEM
In rare cases after rebooting the MiContact Center server the IIS logs grow very quickly.
SYMPTOMS
The IIS logs are full of SignalR events repeating.
2015-03-12 10:33:20 10.9.1.20 POST /ccmwa/signalr/poll transport=longPolling&connectionToken=ktK0S6j-Tfgori3CZPp5PkrEG_vJB_oJbWUMVymUEkIvv3wgE3eU9NOr2mywnOrcia3cmKfqWzcn3plxIjcacErBAl8RkXE6OAcrNNC5MkDHukDRihEFrZ0Bfk6UEPkG0&messageId=F,0|M,0|N,0|O,0&connectionData=[{"Name":"chat"}] 80 - 10.9.1.20 SignalR.Client/1.1.0.0 (Microsoft Windows NT 6.1.7601 Service Pack 1) 200 0 0 15
WORKAROUND
You can stop this SingalR cycle by restarting the Application Pool associated with CCMWa.
1. Open the IIS Manager.2. Go to the Application Pools page.
3. Select the CCMWa application pool.
4. Under Actions, click on Stop.
5. Under Actions, click on Start.
APPLIES TO
MiCC Version 7.X
Keywords: iis log logs signalr grow